Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
2.
J Med Virol ; 94(10): 5033-5037, 2022 10.
Article in English | MEDLINE | ID: covidwho-1981839

ABSTRACT

The severe acute respiratory syndrome coronavirus type 2 (SARS-CoV-2) Omicron was classified as a variant of concern in November 2021. The sublineage BA.2 spreads rapidly worldwide. Currently, there is a lack of data for the parallel comparison of Rapid Antigen Test (RAT) Kits to detect SARS-CoV-2 Omicron BA.2. We evaluated the analytical sensitivity of 12 RAT kits to detect Omicron BA.2 in the present study. Analytical sensitivity was determined by means of the limit of detection (LOD). We prepared a dilution set using a respiratory specimen collected from a COVID-19 patient infected by Omicron BA.2. The reverse transcription-polymerase chain reaction was used as a reference method. The LOD results showed that all 12 RAT kits had comparable analytical sensitivity to detect Omicron BA.2. The RAT kits selected in the current study may be used for the first-line screening of the rapid spreading Omicron BA.2.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , Humans , Immunologic Tests , RNA, Viral/analysis , SARS-CoV-2/genetics
4.
J Clin Virol Plus ; 2(3): 100091, 2022 Aug.
Article in English | MEDLINE | ID: covidwho-1895170

ABSTRACT

Objectives: The World Health Organization (WHO) had designated the SARS-CoV-2 lineage B.1.1.529 as the new Variant of Concern Omicron (VOC-Omicron) on 26th November 20211. Real-time reverse transcription polymerase chain reaction (RT-PCR), single nucleotide polymorphisms (SNP) and whole genome sequencing (WGS) tests were widely employed to detect SARS-CoV-2 and its variant. Yet, the SARS-CoV-2 Omicron detection performance of commercial real-time RT-PCR platforms and SARS-CoV-2 spike SNP assays remain to be elucidated. Methods: In the first part of this study, we evaluated the VOC-Omicron detection performance of three commercial RT-PCR sample-to-answer platforms i.e. Roche cobas® 6800/8800, Roche cobas® Liat®, and Cepheid GeneXpert® systems. The detection performances were compared to one commercial conventional real-time RT-PCR assay (TIB MOLBIOL LightMix Modular SARS and Wuhan CoV E-gene) and one in-house real-time RT-PCR assay targeting RNA-dependent RNA polymerase (RdRP) gene of SARS-CoV-2 in the WHO COVID-19 Reference Laboratory at Public Health Laboratory Services Branch, Centre for Health Protection, Department of Health, The Government of the Hong Kong Special Administrative Region. In the second part of this study, we evaluated the SNP detection performance of four TIB MOLBIOL melting curve-based assays (1. Spike S371L/S373P, 2. Spike E484A, 3. Spike E484K and 4. Spike N501Y) in clinical samples obtained from hospitalized COVID-19 patients in Hong Kong. The SNP results were compared to whole genome sequences generated by Illumina platform. Results: The VOC-Omicron detection limits of three commercial sample-to-answer assays were tested to be ≤ 2.35 Log10 dC/ml. The detection performances of the sample-to-answer platforms were comparable to the two tested conventional real-time RT-PCR assays. The test sensitivities of TIB MOLBIOL VirSNiP SARS-CoV-2 Spike S371L/S373P assay and the Spike E484A assays were 100% and 96.6% respectively and the test specificities of both assays were 100%. An aberrant melting peak at Tm 42-44°C was observed when the specimens with Omicron variant were tested with the TIB MOLBIOL VirSNiP SARS-CoV-2 Spike E484K assay. Notably, the TIB MOLBIOL VirSNiP SARS-CoV-2 Spike N501Y assay failed to detect the spike N501Y mutation of Omicron variant in the tested specimens. Conclusions: The SARS-CoV-2 detection sensitivity of three commercial platforms, Roche cobas® 6800/8800, Roche cobas® Liat®, and Cepheid GeneXpert® systems were shown not to be impacted by the large number of mutations of VOC-Omicron. Also, the signature mutations i.e. Spike S371L/Spike S373P and Spike E484A in VOC-Omicron were correctly identified by the TIB MOLBIOL VirSNiP SARS-CoV-2 Spike S371L/S373P and VirSNiP SARS-CoV-2 Spike E484A assays. Unexpected findings including a shifted melting peak or absence of amplification curve/melting peak were observed when specimens with Omicron variant were tested with the TIB MOLBIOL VirSNiP SARS-CoV-2 Spike E484K assay and Spike N501Y assay, suggesting a potential alert for Omicron variant, prior confirmation by whole genome sequencing.

6.
Dr. Sulaiman Al Habib Medical Journal ; : 1-4, 2022.
Article in English | EuropePMC | ID: covidwho-1877150

ABSTRACT

Background Currently, there is a lack of studies evaluating rapid antigen detection (RAD) kits to detect SARS-CoV-2 B.1.1.529. Objective To evaluate the analytical sensitivity of seven RAD kits to detect SARS-CoV-2 B.1.1.529. Study design The analytical sensitivity was determined by means of limit of detection (LOD). A dilution set using a respiratory specimen collected from a COVID-19 patient infected with SARS-CoV-2 B.1.1.529 was prepared. RT-PCR was used as a reference method. Results The LOD results showed that all seven RAD kits had comparable analytical sensitivity for detection of SARS-CoV-2 B.1.1.529. Conclusions The RAD kits selected in the current study may be used for first-line screening of the recently emerged SARS-CoV-2 B.1.1.529.

8.
Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology ; 2022.
Article in English | EuropePMC | ID: covidwho-1647692
9.
J Virol Methods ; 300: 114396, 2022 Feb.
Article in English | MEDLINE | ID: covidwho-1540815

ABSTRACT

BACKGROUND: Combined nasal-and-throat swabs (CNTS) is less invasive and easy to execute. CNTS also induces lower risk to healthcare workers upon collection. However, there is a lack of data on viral load assessment for population-wide testing. OBJECTIVE: This study assessed if CNTS is suitable as an alternative specimen type for the detection of SARS-CoV-2. METHODS: We assessed the viral load of SARS-CoV-2 in CNTS collected from COVID-19 individuals through the 2-week period of the Universal Community Testing Programme (UCTP) conducted in Hong Kong. In addition, we compared viral loads of SARS-CoV-2 for the paired CNTS and non-CNTS specimens among these individuals. RESULTS: This UCTP identified 48 COVID-19 individuals from nearly 2 million specimens collected. The viral loads of SARS-CoV-2 varied widely, cycle threshold values Ct 16.28-36.94, among symptoms and asymptomatic individuals. The viral loads for the paired CNTS and non-CNTS specimens were comparable. CONCLUSIONS: This study demonstrated that CNTS could be a specimen of choice for diagnosis of SARS-CoV-2.


Subject(s)
COVID-19 , SARS-CoV-2 , Hong Kong , Humans , Nasopharynx , Pharynx , Specimen Handling , Viral Load
12.
Diagn Microbiol Infect Dis ; 101(4): 115490, 2021 Dec.
Article in English | MEDLINE | ID: covidwho-1313037

ABSTRACT

RT-PCR is the gold standard to detect SARS-CoV-2, however, its capacity is limited. We evaluated an automated antigen detection (AAD) test, Elecsys SARS-CoV-2 Antigen (Roche, Germany), for detecting SARS-CoV-2. We compared the limit of detection (LOD) between AAD test, rapid antigen detection (RAD) test; SARS-CoV-2 Rapid Antigen Test (SD Biosensor, Korea), and in-house RT-PCR test. LOD results showed that the AAD test was 100 fold more sensitive than the RAD test, while the sensitivity of the AAD test was comparable to the RT-PCR test. The AAD test detected between 85.7% and 88.6% of RT-PCR-positive specimens collected from COVID-19 patients, false negative results were observed for specimens with Ct values >30. Although clinical sensitivity for the AAD test was not superior or comparable to the RT-PCR test in the present study, the AAD test may be an alternative to RT-PCR test in terms of turn-around time and throughput.


Subject(s)
Antigens, Viral/isolation & purification , COVID-19 Serological Testing/methods , COVID-19/virology , Reagent Kits, Diagnostic , SARS-CoV-2/immunology , SARS-CoV-2/isolation & purification , COVID-19 Nucleic Acid Testing , Diagnostic Tests, Routine , Humans , Limit of Detection , Sensitivity and Specificity , Viral Load
13.
J Clin Virol Plus ; 1(3): 100029, 2021 Sep.
Article in English | MEDLINE | ID: covidwho-1267743

ABSTRACT

Background: Prior to this report, variants of concern for SARS-CoV-2 were only detected from imported cases in Hong Kong. Objective: Multiple cases of SARS-CoV-2 lineage B.1.351 have been identified in local community. We reported the phylogenetic relationship of these cases. Study design: SARS-CoV-2 cases were screened for the key non-synonymous substitutions in spike protein by different assays. Preliminary positive cases were further tested by whole genome sequencing. Results: From Dec 2020 to May 2021, 55 SARS-CoV-2 cases belonged to lineage B.1.351. Among them, eight genomes were clustered together, all of them were local cases with epidemiological link. Conclusions: To track variants of SARS-CoV-2 and to allow early implementation of control measures, SARS-CoV-2 genomic surveillance must be consistently performed.

14.
J Med Virol ; 93(9): 5644-5647, 2021 Sep.
Article in English | MEDLINE | ID: covidwho-1216193

ABSTRACT

In 2020, numerous fast-spreading severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants have been reported. These variants had unusually high genetic changes in the spike (S) protein. In an attempt to understand the genetic background of SARS-CoV-2 viruses in Hong Kong, especially before vaccination, the purpose of this study is to summarize the S protein mutations detected among coronavirus disease 2019 (COVID-19) patients in Hong Kong in 2020. COVID-19 cases were selected every month in 2020. One virus from each case was analyzed. The full encoding region of the S proteins was sequenced. From January 2020 to December 2020, a total of 340 COVID-19 viruses were sequenced. The amino acids of the S protein for 44 (12.9%) were identical to the reference sequence, WIV04 (GenBank accession MN996528). For the remaining 296 sequences (87.1%), a total of 43 nonsynonymous substitution patterns were found. Of the nonsynonymous substitutions found, some of them were only detected at specific time intervals and then they disappeared. The ongoing genetic surveillance system is important. It would facilitate early detection of mutations that can increase infectivity as well as mutations that are selected for the virus to escape immunological restraint.


Subject(s)
COVID-19/virology , SARS-CoV-2 , Spike Glycoprotein, Coronavirus/genetics , Base Sequence , COVID-19/epidemiology , Genome, Viral/genetics , Hong Kong/epidemiology , Humans , Mutation
15.
J Clin Virol ; 134: 104712, 2021 01.
Article in English | MEDLINE | ID: covidwho-1082743

ABSTRACT

BACKGROUND: Currently, there are two rapid antigen detection (RAD) kits from the WHO Emergency Use List for detecting SARS-CoV-2. OBJECTIVE: The Panbio COVID-19 Ag Rapid Test Device was selected to evaluate the performance for detecting SARS-CoV-2. STUDY DESIGN: Analytical sensitivity for the detection of SARS-CoV-2 virus was determined by limit of detection (LOD) using RT-PCR as a reference method. Clinical sensitivity was evaluated by using respiratory specimens collected from confirmed COVID-19 patients. RESULTS: The LOD results showed that the RAD kit was 100 fold less sensitive than RT-PCR. Clinical sensitivity of the RAD kit was 68.6 % for detecting specimens from COVID-19 patients. CONCLUSIONS: The RAD kit evaluated in the present study shared similar performance with another kit from the WHO Emergency Use List, the Standard Q COVID-19 Ag. Understanding the clinical characteristics of RAD kits can guide us to decide different testing strategies in different settings.


Subject(s)
Antigens, Viral/analysis , COVID-19/diagnosis , Reagent Kits, Diagnostic/standards , SARS-CoV-2/immunology , COVID-19/pathology , COVID-19/virology , COVID-19 Testing/methods , Cross Reactions , Hong Kong , Humans , Limit of Detection , Nasopharynx/virology , Pharynx/virology , Reverse Transcriptase Polymerase Chain Reaction , SARS-CoV-2/pathogenicity , World Health Organization
16.
Saf Health Work ; 11(3): 372-377, 2020 Sep.
Article in English | MEDLINE | ID: covidwho-648520

ABSTRACT

Infection risks of handling specimens associated with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) by public health laboratory services teams were assessed to scrutinize the potential hazards arising from the work procedures. Through risk assessments of all work sequences, laboratory equipment, and workplace environments, no aerosol-generating procedures could be identified except the procedures (mixing and transfer steps) inside biological safety cabinets. Appropriate personal protective equipment (PPE) such as surgical masks, protective gowns, face shields/safety goggles, and disposable gloves, together with pertinent safety training, was provided for laboratory work. Proper disinfection and good hand hygiene practices could minimize the probability of SARS-CoV-2 infection at work. All residual risk levels of the potential hazards identified were within the acceptable level. Contamination by gloved hands was considered as a major exposure route for SARS-CoV-2 when compared with eye protection equipment. Competence in proper donning and doffing of PPE accompanied by hand washing techniques was of utmost importance for infection control.

SELECTION OF CITATIONS
SEARCH DETAIL